4-20 IQ INTELLIGENT TRANSMITTER

The model 4-20 IQ is a microprocessor based intelligent sensor transmitter. It comes equipped with a digital display which provides a local reading of the gas concentration. Operating on 14-24 VDC power, it provides a linear 4-20 mA output proportional to the gas concentration, and is housed in an explosion-proof casing. The 4-20 IQ has been UL Classified and CSA Approved Class I, Div. 1, Groups B, C, and D. The 4-20 IQ can operate as a stand-alone instrument, or it can be used with an IST control unit to provide control room readings and alarm relays.

The 4-20 IQ come equipped with an automated calibration feature which allows the unit to be calibrated without manually adjusting any potentiometers. Just apply gas and the 4-20 IQ will do the rest. It couldn't be easier! Interfacing with the 4-20 IQ is accomplished by using a magnetic wand to activate magnetic switches located on the front panel. Thus, all functions can be performed with removing any covers, meaning there's no need to declassify an area being monitored. The 4-20 IQ can be used with any of IST's sensor technologies: infra-red (IR), solid state, catalytic bead, or electrochemical.

4-20 IQ Installation and Instructions Manual (PDF format, 536K)


SM95 STANDARD TRANSMITTER

The model SM95 sensor transmitter is housed in an explosion-proof casing and operates on 14-24 VDC power. The SM95 has been UL Classified and CSA Approved Class I, Div. 1, Groups B, C, and D. The SM95 provides a 4-20 mA linear output proportional to the gas concentration and is calibrated by adjusting potentiomenters located inside the housing. The SM95 can operate as a stand-alone instrument, or it can be used in conjunction with any of IST's complete line of control units which provide control room readings and alarm relays. When used with any of IST's MP Series control units, automated calibration is provided, enabling calibration without the need to adjust potentiometers. Like the 4-20 IQ, the SM95 can be used with any of IST's sensor technologies: infra-red (IR), solid state, catalytic bead, or electrochemical.

SM95 Installation and Instructions Manual (PDF, 567K)


STATIONARY INSTRUMENTSPORTABLE INSTRUMENTSALARM SYSTEMS

For more information, contact:

This site contains a lot of PDF files. If you do not have Acrobat Reader to access these files, download the freeware from adobe.com. If you do not have a high-speed connection, there will be some delay before the document you selected comes up.
    Google
intlsensor.com   Web




View/download PDF versions of:

Gas Sensor Selection Guide (File size: 196K)

Hazardous Gas Data - comprehensive reference on physical and chemical properties for industrial hygiene and occupational health & safety applications (File size: 396K)

PID Correction Factors - a comprehensive reference on PID correction factors for 222 gases (File size: 100K)

Installation & Instructions Manuals for:
a)
MP Controller (File size: 1.1MB)
b) 4-20 IQ (File size: 536K)
c)
SM95 (File size: 567K)

How to Calibrate Sensors
(File size: 427K)

Introduction - from "Hazardous Gas Monitors" book (24 pages)- includes descriptions, "Terms, Definitions & Abbreviations," fully illustrated with charts and graphs, and types of protection (File size: 544K)

About Alarms (File size:148K)

> Grain Silo Fumigation: How to Make a Sensor Work as a Process Analyzer (Australia)

> CO Monitoring in Parking Garages and Tunnels in Switzerland


> H2S Monitoring/Datalogging in Manholes and Lift Stations in Las Vegas, Nevada